Point-of-Care Cepheid Xpert HIV-1 Viral Load Test in Rural African Communities Is Feasible and Reliable


Research Areas

Currently no objects available


Publication Details

Author list: Sikhulile Moyo,a,b Terence Mohammed,a Kathleen E. Wirth,c,d Melanie Prague,e Kara Bennett,f Molly Pretorius Holme,a,e
Lucy Mupfumi,a Philemon Sebogodi,a Natasha O. Moraka,a Corretah Boleo,a Comfort N. Maphorisa,a Boitumelo Seraise,a
Simani Gaseitsiwe,a,d Rosemary M. Musonda,a,d Erik van Widenfelt,a,d Kathleen M. Powis,a,d,g Tendani Gaolathe,a
Eric J. Tchetgen Tchetgen,c,e Joseph M. Makhema,a,d Max Essex,a,d Shahin Lockman,a,d,h Vladimir Novitskya,d

Publication year: 2016

Journal: Journal of Acquired Immune Deficiency Syndromes JAIDS

Volume number: 54

Issue number: 12



Routine monitoring of HIV-1 RNA or viral load (VL) in patients on antiretroviral therapy (ART) is important, but there are multiple impediments to VL testing in resource-constrained settings. An accurate point-of-care (POC) HIV-1 VL test could alleviate many of these challenges. We compared the performance of the Cepheid Xpert HIV-1 VL assay against the laboratory-based Abbott m2000sp/m2000rt assay (Abbott assay). ART-naive individuals participating in the Botswana Combination Prevention Project in 20 communities provided EDTA-blood specimens during household surveys. Both the POC Xpert HIV-1 VL and Abbott assays were performed on specimens sampled from 277 individuals. We found a high correlation between the Xpert HIV-1 VL and Abbott assay results (r 2 0.92; P < 0.001). The overall mean difference in the HIV-1 RNA values obtained by Xpert HIV-1 VL assay and Abbott assay was 0.34 log10 copies/ml (95% confidence interval [CI], 0.26 to 0.40 log10 copies/ml) (P < 0.001). Using a clinically relevant level of 1,000 copies/ml as a threshold, agreement was 90.6% (95% CI, 87.9 to 93.1%), with a sensitivity of 98.6% (95% CI, 97.2 to 100%). The two methods agreed on their detectability of HIV-1 RNA (>40 copies/ml) at 97.1% (95% CI, 95.5 to 98.7%), with a sensitivity of 99.6% (95% CI, 97.2 to 100%). The POC Cepheid Xpert HIV-1 VL assay showed high agreement and accuracy with a laboratory-based method of HIV-1 RNA testing. The POC Xpert HIV-1 VL assay tended to overestimate HIV-1 VL, although the difference was below a clinically relevant threshold of 0.5 log10 copies/ml. The POC Cepheid Xpert HIV-1 VL assay is a promising tool for monitoring patients on ART in southern Africa.


Projects

Currently no objects available


Keywords

Currently no objects available


Documents

Currently no objects available


Last updated on 2025-20-11 at 14:25