Journal article

Performance Analysis of High Voltage Disc Insulators with Different Profiles in Clean and Polluted Environments using Flashover, Withstand Voltage Tests And Finite Element Analysis


Research Areas

Currently no objects available


Publication Details

Author list: A. Ali, A.R. Bhatti, A. Rasool, F. U. Rehman, M.A. Khan, A. Ali, and A. Sherefa

Publication year: 2024

Journal acronym: Sci Rep

ISSN: 2045-2322

eISSN: 2045-2322

URL: https://doi.org/10.1038/s41598-024-71392-5



Severe pollution-induced flashovers on insulators present a pressing challenge to power system safety. The frequent failure of high-voltage insulators, particularly in the polluted environments of Pakistan, poses a critical concern. This paper investigates the impact of insulator profile on reducing pollution flashovers, testing two designs as per IEC standard 60383 and simulated using the Finite Element Method in COMSOL Multiphysics®. The test results revealed that deep under-ribs insulators exhibited a 5.008% reduction in flashover voltage, while alternating shed insulators experienced a 3.233% decrease in polluted conditions compared to clean conditions. Notably, under both clean and polluted conditions, alternating shed insulators consistently outperformed deep under-ribs insulators, with a 25.377% higher flashover voltage in clean conditions and a 27.400% superiority in polluted conditions. Computational analysis through the Finite Element Method in COMSOL Multiphysics shows a consistent pattern in potential distribution with increasing insulator count, but the presence of a pollution layer introduces spikes in the electric field distribution, validating experimental results. These findings highlight the superior performance of alternating shed insulators, especially in polluted environments.


Projects

Currently no objects available


Keywords

Currently no objects available


Documents

Currently no objects available


Last updated on 2025-28-02 at 09:51